Start with flow, not kilowatts

A dryer treats air volume, so its size is a flow rate. The best number is on your compressor’s data sheet or nameplate: free air delivery at the working pressure. Kilowatts are only a rough guide, because compressors differ in efficiency, and fixed-speed, variable-speed and piston machines all deliver differently.

If all you have is the motor power, a typical oil-injected screw compressor at 7 bar gives roughly 0.165 Nm³/min per kW. Use the table for a quick first estimate, then swap in the data-sheet number as soon as you have it.

Reference flow for a typical screw compressor at 7 bar (estimate)
Motor powerApprox. HPNm³/minNm³/hSCFM
7.5 kW10 HP1.27444
11 kW15 HP1.810964
15 kW20 HP2.514987
22 kW30 HP3.6218128
30 kW40 HP5.0297175
37 kW50 HP6.1366216
45 kW60 HP7.4446262
55 kW75 HP9.1545320
75 kW100 HP12.4743437
90 kW125 HP14.9891524
110 kW150 HP18.21,089641
132 kW175 HP21.81,307769

One trap: always check the flow basis. A cubic metre of free air (about 20 °C) and a cubic metre of normal air (0 °C) differ by around 7 to 8 percent, and standard cubic feet use another reference again. If two quotes use different bases, you can’t compare them.

A dryer’s rated flow is for one set of conditions

Catalogues usually rate a refrigerated dryer at one reference point, for example 7 bar, 35 °C inlet air, 25 °C ambient and a +3 °C pressure dew point. Your site probably isn’t that. Hotter inlet air carries a lot more water, a hotter room makes the refrigeration work harder, and lower pressure means more air volume for the same amount of air.

The factors below are typical industry reference values. Multiply the rated flow by each one that applies and you get what the dryer can really handle at your site. Your dryer’s own data sheet always has the final say.

Typical capacity correction factors (reference values)
ConditionValueFactor
Inlet air temperature30 °C1.18
Inlet air temperature35 °C (rating)1.00
Inlet air temperature40 °C0.82
Inlet air temperature45 °C0.69
Inlet air temperature50 °C0.58
Ambient temperature25 °C (rating)1.00
Ambient temperature35 °C0.84
Ambient temperature40 °C0.76
Ambient temperature45 °C0.68
Working pressure5 bar0.86
Working pressure7 bar (rating)1.00
Working pressure10 bar1.13
Pressure dew point+3 °C (rating)1.00
Pressure dew point+7 °C1.19

Worked example: same compressor, two very different sites

Take a 37 kW screw compressor at 7 bar. It delivers about 6.1 Nm³/min. A dryer running flat out has nothing in reserve for surges, a dusty condenser or future expansion, so we leave a margin. The LP Dryer Finder aims for a dryer load of no more than 77 percent of the corrected capacity. Same approach here:

When a dryer is undersized you notice it in summer: dew point creeps up, water shows in the lines and people blame the compressor. Want us to run your numbers? Send them on WhatsApp or through the contact form.

  • Mild site (35 °C inlet, 25 °C ambient, +3 °C dew point): factor 1.00. Required rated flow: 6.1 ÷ 0.77, about 8 Nm³/min.
  • Hot site (45 °C inlet, 40 °C ambient, +3 °C dew point): factor 0.69 × 0.76, about 0.52. Required rated flow: 6.1 ÷ (0.52 × 0.77), about 15 Nm³/min.
  • Same compressor, but the hot site needs a dryer with nearly double the rated capacity. Pick by kilowatts alone and you’ll be badly undersized.

Cool the air before you buy a bigger dryer

On a hot site the cheapest extra capacity is often removing heat ahead of the dryer. A healthy compressor aftercooler, a separator with a working drain and, where needed, a pre-cooling unit all cut the water load and bring the dryer back toward its rating. Where cooling water is available and the room is too hot for air-cooled equipment, a water-cooled dryer can be the better answer.

Also watch the air path. A dryer that breathes its own hot exhaust loses far more capacity than any table shows. Keep clearance around the intake and give hot air a way out of the room.

Cases that change the answer

  • Several compressors on one dryer: add up the flows that can run at the same time, not every nameplate.
  • Variable-speed compressors: size for the maximum flow and the lowest pressure the dryer will see.
  • Need a dew point below +3 °C, or have pipes that get below freezing: a refrigerated dryer is the wrong tool. See our refrigerated or desiccant guide.
  • Oil-flooded piston compressors or a lot of oil carry-over: put a coalescing filter ahead of the dryer.
  • High altitude or very dusty sites: ask for the maker’s correction and plan condenser cleaning.

What to send us for a quote

Don’t have everything? Send what you know. A compressor nameplate photo and your country are enough for us to start, and we’ll confirm the rest with you. Reach us on WhatsApp or the contact form.

  • Compressor model, motor power and free air delivery (with the flow basis if you know it).
  • Working pressure at the dryer, and the lowest pressure you expect.
  • Highest inlet air temperature and highest ambient temperature at the dryer.
  • Required pressure dew point, and the coldest pipe downstream.
  • Voltage, frequency and phase. Air-cooled or water-cooled.
  • Country and site: indoors or outdoors, dust, coastal air, altitude.